APC Easy UPS /On-Line SRV Ext. Runtime 10000VA 230V /with External Battery Pack /SRV10KIL

AED 12,679.00

SAVE 3856.00 (23%)

  • 230 V input Voltage
  • 170 – 300 Adjustable, 180 – 287V
  • Battery voitage-240 v
  • Lead-acid battery
  • 3-5 year(s) Battery life
  • 0…40 °C Operating-Temperature
  • Line interactive
  • 76.5kg
  • 2 years repair or replace
  • color-Black
  • Battery Charge Power (Watts)-1170 Watts

More Info

Out of stock

when this product is back in stock

Categories: , , Brand:

Buy APC Easy UPS On-Line SRV Ext. Runtime 10000VA 230V with External Battery Pack SRV10KIL

This APC Single phase Easy UPS is designed for IT professionals or network administrators to maintain business uptime and continuity. This 2000VA double-conversion on-line 4U rackmount UPS provides pure sine wave power and extended runtime to support critical electronics during power disruptions. The SRV comes with IEC 320 C14 input and 4x Brazilian 2P+T outlets. The On-Line UPS has a intelligent card slot for optional Network Management Card (AP9544, SRVSMB001, VGL9601l) that enables network-based UPS monitoring and management. The UPS can connect to EcoStruxure IT or third-party centralized management platforms. The Built-in automatic and manual bypass provide seamless power to the load even in the event of an internal detected fault or error in UPS. The UPS and the built-in lead-acid battery has a 2-year warranty. Ideal for small data centers, manufacturing facilities, computer rooms, network storage devices, telecommunication, and healthcare IT.

Batteries & Runtime

Run Time : View Run time Graph

Operational Features

Manageability

  • USB connectivity: Provides management of the UPS via a USB port (not available on all models).
  • Serial connectivity: Provides management of the UPS via a serial port.
  • Network manageable: Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded.
  • LED status indicators:Provide easy-to-read status of the unit and utility power conditions.
  • LCD graphics display: Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • SmartSlot : Customize UPS capabilities with management cards.

Serviceability

    • Disconnected battery notification: Warns when a battery is not available to provide backup power.
    • Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.
    • Audible alarms: Provides notification of changing utility power and UPS power conditions
    • Predictive failure notification: Provides early-warning fault analysis ensuring proactive component replacement.

APC Easy UPS On-Line standard features and applications :

Standard Models :
Built-in batteries for Plug-and-Play will provide a ~2 to 4 min typical battery backup power for the connected equipment at full load.
Extended-Run Models :
Extended-run models have the capability to add external battery packs to scale runtime from minutes to hours, making them ideal for mixed load applications.
UXI Models :
UXI series has the capability to add third-party external batteries to get longer runtime, providing flexibility when selecting batteries.

Safety and General Information

Deenergizing safety:

The UPS contains internal batteries and may present a shock hazard even when disconnected from the branch circuit (mains). Before installing or servicing the equipment check that the:

  • Input circuit breaker is in the OFF position.
  • Internal UPS batteries are removed.
  • XLBP battery modules are disconnected.
Electrical safety:

  • Use tools with insulated handles.
  • Do not handle any metallic connector before power has been disconnected.
  • For models with a hardwired input, the connection to the branch circuit (mains) must be performed by a qualified electrician.
  • The protective earth conductor for the UPS carries the leakage current from the load devices (computer equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the UPS. The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors. The conductor will typically be green, with or without a yellow stripe.
  • Leakage current for a pluggable, Type A UPS may exceed 3.5 mA when a separate ground terminal is used.
  • The UPS input ground conductor must be properly bonded to protective earth at the service panel.
  • If the UPS input power is supplied by a separately derived system, the ground conductor must be properly bonded at the supply transformer or motor generator set.
Battery safety :

  • Batteries typically last for two to five years. Environmental factors impact battery life. Elevated ambient temperatures,poor quality utility power, and frequent short duration discharges will shorten battery life. Batteries should be replaced before end of life.
  • Replace batteries immediately when the unit indicates battery replacement is necessary.
  • When replacing batteries, replace with the same number and type of batteries as originally installed in the equipment.
  • Schneider Electric uses Maintenance-Free sealed Lead Acid batteries. Under normal use and handling, there is no contact with the internal components of the battery. Over charging, over heating or other misuse of batteries can result in a discharge of battery electrolyte. Released electrolyte is toxic and may be harmful to the skin and eyes.
  • CAUTION: Before installing or replacing the batteries, remove jewelry such as chains, wristwatches and rings.Use tools with insulated handles. High short circuit current through conductive materials could cause severe burns.
  • CAUTION: Do not dispose of batteries in a fire. The batteries may explode
  • CAUTION: Do not open or mutilate batteries. Released material is harmful to the skin and eyes and may be toxic.
Output
Max Configurable Power (Watts) 10.0kWatts / 10.0kVA
UPS Type Double conversion online
Input
Input Frequency 40 – 70 Hz Auto sensing
Input Voltage Range for Main Operations 110 – 300 Half load, 176 – 300 Full loadV
Other Input Voltages 220 V, 240 V
Batteries
Battery Type Lead-acid battery
Typical Recharge Time 9hour(s)
Expected Battery Life (years) 3 – 5
Battery Charge Power (Watts) 1.17kWatts
Communication & Management
Control Panel Multifunction LCD status and control console Audible Alarm
Interface Port(s) DB-9 RS-232, Intelligent Smart Slot, USB
General
Warranty 2 years repair or replace
Environmental
Operating Temperature 0 – 40 °C
Storage and Transportation Temperatue -15…60 °C
Acoustic 58 dB
Operating Relative Humidity 0 – 95 (Non-condensing) %
Operating Elevation 0 – 3000meters
Storage Temperature -15 – 60 °C
Operating altitude 0...3000 m
Relative humidity 0…95 % non-condensing
Mounting mode Not rack-mountable

Reviews

There are no reviews yet.

Be the first to review “APC Easy UPS /On-Line SRV Ext. Runtime 10000VA 230V /with External Battery Pack /SRV10KIL”

Your email address will not be published. Required fields are marked *

Shipping Details

    • Please pay more attention to your order address which must match your shipping address. ( Please leave your full name. It is very important)
    • Items will be shipped within 1 - 3 days after payment.
    Shipping By Shipping Cost Estimated Delivery Time Tracking Information
    Promise Computer Technology Based on Countries 1-3 days Not available

Compare Products